BIXOLON SRP-352plusIII Manuel d'utilisateur Page 101

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 120
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 100
SRP-350/352plusIII
Rev. 1.00 BIXOLON
- 101 -
GS W
Function:
Set printing area width
Code:
ASCII
GS
W
nL
nH
Hex
1D
57
nL
nH
Decimal
29
87
nL
nH
Range:
0 ≤ nL ≤ 255, 0 ≤ nH ≤ 255
Default:
SRP-350plusIII:
(nL + nH x 256)=512 (nL=0, nH=2) (When 80mm width of paper used)
SRP-352plusII:
(nL + nH x 256)=576 (nL=64, nH=2) (When 80mm width of paper used)
Description:
This command sets the printing area width to [(nL + nH x 256) x (horizontal motion units)].
Remarks:
The printing area width is not effective in page mode. If the printing area width is enabled in page mode, the setting is
available when the printer returns to standard mode.
When (left margin + printing area width) exceeds the printable area, the printing area width is automatically set to
(printing area width - left margin).
The setting of this command remains effective until ESC @, printer reset or power cycling is executed.
Printable area
Left margin
Printing area width
Differences:
None